Chinese Journal of Radiological Medicine and Protection ; (12): 297-302, 2019.
Article in Chinese | WPRIM | ID: wpr-745256

ABSTRACT

Objective To study the methods to estimate absorbed dose to eye lens of infants from CT scanning using different protocols and try to find a practical quick way for estimating absorbed dose to eye lens.Methods By scanning one-year old anthropomorphic phantom using 7 kinds of different protocols,all TLDs were measured for final estimation of absorbed dose to eye lens using two different dose conversion methods.Meanwhile,linear regression equation was established between absorbed dose to eye lens and CTDI.Results Absorbed doses to eye lens of infants from children CT scanning using 7 kinds of different protocols were (9.96±0.69) mGy in head axis,(7.01±0.42) mGy in head helical,(12.60± 0.97) mGy in sinus,(12.97±0.42) mGy in inner ear,(0.63±0.03) mGy in neck soft tissue,(8.89± 0.44) mGy in cervical vertebra,and (0.34± 0.01) mGy in chest,respectively.There were statistically significant difference in doses among different groups (F =846.826,P < 0.05).For different scanning locations,there was linear relation between absorbed dose to eye lens and CTDI(r=0.986-0.999,P< 0.05).Conclusions Absorbed dose to eye lens of infants from children CT scaning with single dose may not be above threshold dose.In addition,absorbed dose to eye lens can be estimated quickly by linear regression equation between absorbed dose to eye lens and CTDI.

2.
The Journal of Practical Medicine ; (24): 1983-1986, 2016.
Article in Chinese | WPRIM | ID: wpr-494578

ABSTRACT

Objective To compare the application of Goldman , CARPREG and ZAHARA in predicting cardiac outcomes in pregnant women with congenital heart disease. Methods A retrospective analysis of 144 pregnant women with CHD , enrolled in The Third Affiliated Hospital of Guangzhou Medical University between Jan 1992 and June 2015 was conducted. The mortality and the incidence of cardiac events were counted by three risk estimation methods. The sensitivity and calibration of three systems were compared by using Hosmer-Lemeshow goodness of-fit analysis and Aera Under Curve (AUC). Results In terms of mortality rates, the sensitivity of CARPREG was higher than that of Goldman (AUC:0.874 and 0.889 respectively;P = 0.568 >0.05);. In terms of the incidence of cardiac events, the sensitivity of ZAHARA was higher than that of Goldman (AUC:0.912 and 0.773 respectively;P = 0.063 > 0.05); Conclusions All 3 risk estimation methods have good performance in sensitivity of predicting the incidence of cardiac events and mortality in pregnant women with CHD. The ZAHARA has a better calibration in predicting the incidence of cardiac events , and we recommend ZAHARA as the first choice of evaluation system for this kind of patients.

SELECTION OF CITATIONS
SEARCH DETAIL